| Emerson Process Management | Rosemount 5300 Series | 0107 | Advanced Configuration | Transducer |
| Rosemount 5400 Series | 0203 | Advanced Configuration | Transducer |
| Description: | Empty Tank |
| Parent: | AMPLITUDE_THRESHOLD_CURVE |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Tank is empty |
| Enumerations: | 1 – Tank is empty 2 – Tank is not empty |
| + | 2 reference(s) hidden. |
| Emerson Process Management | Rosemount 5300 Series | 0107 | Transducer | |
| Rosemount 5400 Series | 0203 | Transducer |
| Description: | Write protect state |
| Parent: | ENV_WRITE_PROTECT |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Write protect state |
| Enumerations: | 0 – Undefined 1 – Unlocked 2 – Locked |
| + | 2 reference(s) hidden. |
| Emerson Process Management | Rosemount 5300 Series | 0107 | Advanced Configuration | Transducer |
| Rosemount 5400 Series | 0203 | Advanced Configuration | Transducer |
| Description: | Simulation Mode Action |
| Parent: | SIMULATION_MODE |
| Size: | 4 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | bit Array |
| Help: | Simulation Mode Action |
| Enumerations: | 11 – Volume upper 12 – Volume lower 13 – Upper product thickness 14 – Interface signal strength 15 – Interface level rate 16 – Interface distance 17 – Interface level 18 – Level rate 19 – Signal strength 20 – Volume 21 – Ullage 22 – Level 23 – All 29 – Enable: Force Fail Alarm 30 – Enable: Force Meas Alarm 31 – Simulation enabled |
| + | 1 reference(s) hidden. |
| Thermo Fisher Scientific | LevelPRO | 0101 | Analog Input | Transducer |
| Description: | ALARM ACTION |
| Parent: | ALARM1 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Action taken on Alarm |
| Enumerations: | 0 – Nothing 1 – Control relay 1 2 – Control relay 2 3 – Output 1 to FAULT LOW 5 – Output 1 to FAULT HIGH |
| + | 1 reference(s) hidden. |
| Thermo Fisher Scientific | LevelPRO | 0101 | Analog Input | Transducer |
| Description: | ALARM ACTION |
| Parent: | ALARM2 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Action taken on Alarm |
| Enumerations: | 0 – Nothing 1 – Control relay 1 2 – Control relay 2 3 – Output 1 to FAULT LOW 5 – Output 1 to FAULT HIGH |
| + | 1 reference(s) hidden. |
| Thermo Fisher Scientific | LevelPRO | 0101 | Analog Input | Transducer |
| Description: | ALARM ACTION |
| Parent: | ALARM3 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Action taken on Alarm |
| Enumerations: | 0 – Nothing 1 – Control relay 1 2 – Control relay 2 3 – Output 1 to FAULT LOW 5 – Output 1 to FAULT HIGH |
| + | 1 reference(s) hidden. |
| Thermo Fisher Scientific | LevelPRO | 0101 | Analog Input | Transducer |
| Description: | ALARM ACTION |
| Parent: | ALARM4 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Action taken on Alarm |
| Enumerations: | 0 – Nothing 1 – Control relay 1 2 – Control relay 2 3 – Output 1 to FAULT LOW 5 – Output 1 to FAULT HIGH |
| + | 1 reference(s) hidden. |
| Emerson Process Management | Rosemount 5300 Series | 0107 | Advanced Configuration | Transducer |
| Description: | Env Set Start Code Action |
| Parent: | ENV_SET_START_CODE |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Unsigned Integer |
| Help: | Env Set Start Code Action |
| + | 1 reference(s) hidden. |
| Emerson Process Management | Rosemount 5300 Series | 0107 | Advanced Configuration | Transducer |
| Description: | Constant Threshold |
| Parent: | SET_CONSTANT_THRESHOLD |
| Size: | 4 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | bit Array |
| Help: | Constant Threshold |
| Enumerations: | 1 – Set ATC Threshold to value 1 |