Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
ATT_AI_BLOCK_ALMS_ACTIVE ATT_BLOCK_ALMS_ACTIVE BLOCK_ALMS_ACTIVE

+39 reference(s) hidden.
Biffi Italia srlF02-FF0106Resource
Analog InputFunction
Analog OutputFunction
Discrete InputFunction
Discrete OutputFunction
Proportional Integral DerivativeFunction
Ohmart/VEGA CorporationGEN20000302Resource
Analog InputFunction
Analog OutputFunction
Rotork Controls LtdFF01 Mk2 Network Interface0102Analog InputFunction
Analog OutputFunction
Discrete InputFunction
Discrete OutputFunction
Proportional Integral DerivativeFunction
TopWorx Inc.SCM-FF0203Resource
Analog InputFunction
Discrete InputFunction
Discrete OutputFunction
Tyco Valves & ControlsAVID SmartCal FF0201Resource
Analog InputFunction
Analog OutputFunction
Proportional Integral DerivativeFunction
AVID ZR-F0302Resource
Discrete InputFunction
Discrete OutputFunction
Westlock ControlsFPAC-ESD0101Resource
Discrete InputFunction
Discrete OutputFunction
0301Resource
Discrete InputFunction
Discrete OutputFunction
Intellis ICoT FF0101Resource
Analog InputFunction
Analog OutputFunction
Proportional Integral DerivativeFunction
0201Resource
Analog InputFunction
Analog OutputFunction
Proportional Integral DerivativeFunction
Description:Detailed Block Errors
Size:4
Category:Vendor
Access:View Only
Type:bit Array
Enumerations:0 – Bad Execution Period
0 – Bad Execution Period
0 – Bad Execution Period
0 – Bad Execution Period
0 – Bad Execution Period
0 – Bad Execution Period
1 – Invalid Mode
1 – Invalid Mode
1 – Invalid Mode
1 – Invalid Mode
1 – Invalid Mode
1 – Invalid Mode
2 – Mode Error
2 – Mode Error
2 – Mode Error
2 – Mode Error
2 – Mode Error
2 – Mode Error
3 – Invalid Transducer Value
3 – Invalid Transducer Value
3 – Invalid Transducer Value
3 – Invalid Transducer Value
3 – Invalid Transducer Value
3 – Invalid Transducer Value
4 – Bad Sim Value
4 – Bad Sim Value
4 – Bad Sim Value
4 – Bad Sim Value
4 – Bad Sim Value
4 – Bad Sim Value
5 – Bad LType
5 – Bad LType
5 – Bad LType
5 – Bad LType
5 – Bad LType
5 – Bad LType
6 – Xducer Mismatch
6 – Xducer Mismatch
6 – Xducer Mismatch
6 – Xducer Mismatch
6 – Xducer Mismatch
6 – Xducer Mismatch
7 – Bad Alert
7 – Bad Alert
7 – Bad Alert
7 – Bad Alert
7 – Bad Alert
7 – Bad Alert
8 – Invalid Feature Selected
8 – Invalid Feature Selected
8 – Invalid Feature Selected
8 – Invalid Feature Selected
8 – Invalid Feature Selected
8 – Invalid Feature Selected
9 – Invalid Cycle Select
9 – Invalid Cycle Select
9 – Invalid Cycle Select
9 – Invalid Cycle Select
9 – Invalid Cycle Select
9 – Invalid Cycle Select
10 – Device Fail Safe Set
10 – Device Fail Safe Set
10 – Device Fail Safe Set
10 – Device Fail Safe Set
10 – Device Fail Safe Set
10 – Device Fail Safe Set
11 – Lock Semaphore Failure
11 – Lock Semaphore Failure
11 – Lock Semaphore Failure
11 – Lock Semaphore Failure
11 – Lock Semaphore Failure
11 – Lock Semaphore Failure
12 – Active Block Err
12 – Active Block Err
12 – Active Block Err
12 – Active Block Err
12 – Active Block Err
12 – Active Block Err
13 – Simulation Locked Out
13 – Simulation Locked Out
13 – Simulation Locked Out
13 – Simulation Locked Out
13 – Simulation Locked Out
13 – Simulation Locked Out
14 – Invalid Key
14 – Invalid Key
14 – Invalid Key
14 – Invalid Key
14 – Invalid Key
14 – Invalid Key
15 – License Timeout
15 – License Timeout
15 – License Timeout
15 – License Timeout
15 – License Timeout
15 – License Timeout
16 – Invalid Device Error
16 – Invalid Device Error
16 – Invalid Device Error
16 – Invalid Device Error
16 – Invalid Device Error
16 – Invalid Device Error
17 – Invalid Transducer Units
17 – Invalid Transducer Units
17 – Invalid Transducer Units
17 – Invalid Transducer Units
17 – Invalid Transducer Units
17 – Invalid Transducer Units
18 – NV Memory Error
18 – NV Memory Error
18 – NV Memory Error
18 – NV Memory Error
18 – NV Memory Error
18 – NV Memory Error
19 – Internal Error
19 – Internal Error
19 – Internal Error
19 – Internal Error
19 – Internal Error
19 – Internal Error

+12 reference(s) hidden.
Biffi Italia srlF02-FF0106Analog InputFunction
Analog OutputFunction
Discrete InputFunction
Tyco Valves & ControlsAVID SmartCal FF0201Analog OutputFunction
Discrete InputFunction
AVID ZR-F0302Analog InputFunction
Westlock ControlsFPAC-ESD0101Analog InputFunction
0301Analog InputFunction
Intellis ICoT FF0101Analog OutputFunction
Discrete InputFunction
0201Analog OutputFunction
Discrete InputFunction
Description:BLOCK_ALARMS_ACTIVE
Size:4
Category:Vendor
Access:View Only
Type:bit Array
Help:Enumerations of the active blocks alarms for improved debugging.
Enumerations:19 – Both Contacts Closed
19 – Both Contacts Closed
19 – Both Contacts Closed
20 – Conflicting Channels Assigned
20 – Conflicting Channels Assigned
20 – Conflicting Channels Assigned
21 – Open without Close
21 – Open without Close
21 – Open without Close
22 – No Output Channels
22 – No Output Channels
22 – No Output Channels
23 – Out Of Service
23 – Out Of Service
23 – Out Of Service
24 – Invalid Input
24 – Invalid Input
24 – Invalid Input
25 – Bad Output Configuration
25 – Bad Output Configuration
25 – Bad Output Configuration
26 – Invalid Mode
26 – Invalid Mode
26 – Invalid Mode
27 – Fault State Active
27 – Fault State Active
27 – Fault State Active
28 – Initial Channel Configuration
28 – Initial Channel Configuration
28 – Initial Channel Configuration
29 – Invalid Action Element
29 – Invalid Action Element
29 – Invalid Action Element