| ABB Automation Products GmbH | 2600T Series - Model 266 P-dP | 0101 | Pressure | Transducer |
| 2600T Series 263/265 | 0101 | Pressure | Transducer | |
| 2600T Series 267/269 | 0201 | Pressure | Transducer | |
| Temperature | Transducer | |||
| FCM2000 | 0101 | FCM2000 | Transducer | |
| FSM4000 | 0201 | Flow with Calibration | Transducer | |
| FXE4000 | 0202 | Flow with Calibration | Transducer | |
| Endress+Hauser | Cerabar S | 0203 | Pressure | Transducer |
| Foxboro | I/A Series IMV25 Pressure Transmitter | 1001 | Transducer | |
| Pressure | Transducer | |||
| IASPT10 | 1701 | Pressure | Transducer | |
| Foxboro-Eckardt | 240FF | 0101 | Pressure | Transducer |
| Fuji Electric Corporation | FCX-AIII Series | 0101 | Pressure | Transducer |
| Ohmart/VEGA Corporation | GEN2000 | 0302 | Analog Input | Function |
| Oval Corporation | Vortex EX DELTA | 0102 | Transducer | |
| 0201 | Transducer | |||
| Siemens AG | SITRANS P DSIII/P300 FF | 0101 | Pressure | Transducer |
| Softing AG | Pressure Transmitter | 0101 | Analog Input | Transducer |
| Temperature Transmitter | 0101 | Analog Input | Transducer | |
| Yokogawa Electric Corporation | Digital YEWFLO | 0104 | DYF | Transducer |
| EJX | 0303 | Sensor | Transducer | |
| ROTAMASS / RCCT3 | 0102 | ROTAMASS | Transducer |
| Description: | Calibration Low Point |
| Unit: | CAL_UNIT |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | The lowest calibrated value. |
| + | 12 reference(s) hidden. |
| Emerson Process Management | Rosemount 2051 | 0101 | Transducer | |
| Rosemount 3051 | 1707 | Pressure | Transducer | |
| Rosemount 644 | 0107 | Sensor | Transducer | |
| Rosemount 8742C | 0501 | Transducer | ||
| Rosemount 8800 | 0701 | Transducer | ||
| 0901 | Transducer | |||
| Rosemount Analytical Oxymitter 5000 | 0303 | Transducer | ||
| 0401 | Transducer | |||
| MTL Instruments | 9331-T1 | 0101 | Sensor | Transducer |
| Yokogawa Electric Corporation | EXA ISC202 | 0201 | ISC2020-F | Transducer |
| EXA PH202 | 0201 | PH202-F | Transducer | |
| EXA SC202 | 0201 | SC202-F | Transducer |
| Description: | Calibration Low Point |
| Unit: | CAL_UNIT |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | The lowest calibrated value. |
| + | 3 reference(s) hidden. |
| VEGA Grieshaber KG | VEGABAR | 0301 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Lowest calibrated value. For calibration of the low limit point you give the low measurement value (pressure) to the sensor and transfer this point as LOW to the transmitter. Unit derives from 'Sensor_range.unit' |
| + | 3 reference(s) hidden. |
| VEGA Grieshaber KG | VEGACAL | 0301 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Min/max-adjustment: Lower calibrated point of the sensor. It refers to 'Cal_level_lo'. The unit is defined in 'Sensor_range.unit' |
| + | 3 reference(s) hidden. |
| VEGA Grieshaber KG | VEGADIF | 0401 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Lowest calibrated value. For calibration of the low limit point you give the low measurement value (pressure) to the sensor and transfer this point as LOW to the transmitter. Unit derives from 'Sensor_range.unit' |
| + | 3 reference(s) hidden. |
| VEGA Grieshaber KG | VEGAFLEX | 0301 | Analog Input | Transducer |
| VEGASON | 0301 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Min/max-adjustment: Lower calibrated point of the sensor. It refers to 'Cal_level_lo'. The unit is defined in 'Sensor_range.unit' |
| + | 3 reference(s) hidden. |
| WIKA Alexander Wiegand SE & Co. KG. | IPT-1x-4 | 0301 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Lowest calibrated value. For calibration of the low limit point you give the low measurement value (pressure) to the sensor and transfer this point as LOW to the transmitter. Unit derives from 'Sensor_range.unit' |
| + | 2 reference(s) hidden. |
| Emerson Process Management | Rosemount Analytical 5081-pH/ORP-FF | 0101 | Transducer | |
| 0204 | Transducer |
| Description: | Calibration Low Point |
| Minimum Range: | 0 |
| Maximum Range: | 14 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Cal point lo -- manual sample value 1 calib |
| + | 2 reference(s) hidden. |
| Magnetrol | Eclipse Enhanced Model 705 3x | 0201 | Analog Input | Transducer |
| Orion Jupiter Model 2xx | 0101 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Unit: | SENSOR_UNIT |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Cal Point Lo is the lower calibrated point of Sensor Value in sensor units. It refers to Probe Level Lo. |
| + | 2 reference(s) hidden. |
| Smar International Co. | IF302 | 0407 | Transducer | |
| LD292 | 0407 | Transducer |
| Description: | Calibration Low Point |
| Unit: | CAL_UNIT |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | The lowest calibrated point. |
| + | 2 reference(s) hidden. |
| Yamatake Corporation | DSTJ 3000 NewAce | 0103 | DST | Transducer |
| 0104 | DST | Transducer |
| Description: | Calibration Low Point |
| Unit: | CAL_UNIT |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Low value for Cal routine |
| + | 1 reference(s) hidden. |
| ABB Automation Products GmbH | TB82PH | 0101 | TB82PH pH, ORP, pION | Transducer |
| Description: | Calibration Low Point |
| Unit: | CAL_UNIT |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | CAL_POINT_LO: Calibration lowest point.TWO-POINT calibration procedure: 1. For PRIMARY VALUE TYPE=pH write the two-point calibration temperature into CAL_TEMP. Send the value to the instrument. (For ORP and pION this step is not necessary.)2. Apply low point calibration input. Observe PRIMARY VALUE and make sure it is stable. Write the desired calibration value into CAL_POINT_LO.3. Apply high point calibration input. Observe PRIMARY VALUE and make sure it is stable. Write the desired calibration value into CAL_POINT_HI.4. Any calibration errors will be available in EXTENDED STATUS. |
| + | 1 reference(s) hidden. |
| Siemens AG | SITRANS LR250 | 0101 | Level | Transducer |
| Description: | Calibration Low Point |
| Unit: | SENSOR_RANGE.UNITS_INDEX |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | No Help Available |
| + | 1 reference(s) hidden. |
| VEGA Grieshaber KG | VEGACAL | 0101 | Analog Input | Transducer |
| Description: | Calibration Low Point |
| Category: | Standard |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | Min/Max-Adjustment: This is the lower calibrated point of the sensor. It refers to 'cal_level_lo'. The unit is defined in 'sensor_range.Units Index' |