Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
+13 like(s) hidden.
CAL_POINT_LO_1 CAL_POINT_LO_2 CAL_POINT_LO_3 CAL_POINT_LO_BACKUP CAL_POINT_LO_COUNTS CAL_POINT_LO_DATE CAL_POINT_LO_FACTORY LE_CAL_POINT_LO O2_CAL_POINT_LO PH_CAL_POINT_LO QS_CAL_POINT_LO STATIC_PRESSURE_CAL_POINT_LO STATIC_P_CAL_POINT_LO

+23 reference(s) hidden.
ABB Automation Products GmbH2600T Series - Model 266 P-dP0101PressureTransducer
2600T Series 263/2650101PressureTransducer
2600T Series 267/2690201PressureTransducer
TemperatureTransducer
FCM20000101FCM2000Transducer
FSM40000201Flow with CalibrationTransducer
FXE40000202Flow with CalibrationTransducer
Endress+HauserCerabar S0203PressureTransducer
FoxboroI/A Series IMV25 Pressure Transmitter1001Transducer
PressureTransducer
IASPT101701PressureTransducer
Foxboro-Eckardt240FF0101PressureTransducer
Fuji Electric CorporationFCX-AIII Series0101PressureTransducer
Ohmart/VEGA CorporationGEN20000302Analog InputFunction
Oval CorporationVortex EX DELTA0102Transducer
0201Transducer
Siemens AGSITRANS P DSIII/P300 FF0101PressureTransducer
Softing AGPressure Transmitter0101Analog InputTransducer
Temperature Transmitter0101Analog InputTransducer
Yokogawa Electric CorporationDigital YEWFLO0104DYFTransducer
EJX0303SensorTransducer
ROTAMASS / RCCT30102ROTAMASSTransducer
Description:Calibration Low Point
Unit:CAL_UNIT
Category:Standard
Access:Engineer
Type:32 bit Float
Help:The lowest calibrated value.

+12 reference(s) hidden.
Emerson Process ManagementRosemount 20510101Transducer
Rosemount 30511707PressureTransducer
Rosemount 6440107SensorTransducer
Rosemount 8742C0501Transducer
Rosemount 88000701Transducer
0901Transducer
Rosemount Analytical Oxymitter 50000303Transducer
0401Transducer
MTL Instruments9331-T10101SensorTransducer
Yokogawa Electric CorporationEXA ISC2020201ISC2020-FTransducer
EXA PH2020201PH202-FTransducer
EXA SC2020201SC202-FTransducer
Description:Calibration Low Point
Unit:CAL_UNIT
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:The lowest calibrated value.

+3 reference(s) hidden.
VEGA Grieshaber KGVEGABAR0301Analog InputTransducer
Description:Calibration Low Point
Category:Standard
Access:Engineer
Type:32 bit Float
Help:Lowest calibrated value. For calibration of the low limit point you give the low measurement value (pressure) to the sensor and transfer this point as LOW to the transmitter. Unit derives from 'Sensor_range.unit'

+3 reference(s) hidden.
VEGA Grieshaber KGVEGACAL0301Analog InputTransducer
Description:Calibration Low Point
Category:Standard
Access:Engineer
Type:32 bit Float
Help:Min/max-adjustment: Lower calibrated point of the sensor. It refers to 'Cal_level_lo'. The unit is defined in 'Sensor_range.unit'

+3 reference(s) hidden.
VEGA Grieshaber KGVEGADIF0401Analog InputTransducer
Description:Calibration Low Point
Category:Standard
Access:Engineer
Type:32 bit Float
Help:Lowest calibrated value. For calibration of the low limit point you give the low measurement value (pressure) to the sensor and transfer this point as LOW to the transmitter. Unit derives from 'Sensor_range.unit'

+3 reference(s) hidden.
VEGA Grieshaber KGVEGAFLEX0301Analog InputTransducer
VEGASON0301Analog InputTransducer
Description:Calibration Low Point
Category:Standard
Access:Engineer
Type:32 bit Float
Help:Min/max-adjustment: Lower calibrated point of the sensor. It refers to 'Cal_level_lo'. The unit is defined in 'Sensor_range.unit'

+3 reference(s) hidden.
WIKA Alexander Wiegand SE & Co. KG.IPT-1x-40301Analog InputTransducer
Description:Calibration Low Point
Category:Standard
Access:Engineer
Type:32 bit Float
Help:Lowest calibrated value. For calibration of the low limit point you give the low measurement value (pressure) to the sensor and transfer this point as LOW to the transmitter. Unit derives from 'Sensor_range.unit'

+2 reference(s) hidden.
Emerson Process ManagementRosemount Analytical 5081-pH/ORP-FF0101Transducer
0204Transducer
Description:Calibration Low Point
Minimum Range:0
Maximum Range:14
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:Cal point lo -- manual sample value 1 calib

+2 reference(s) hidden.
MagnetrolEclipse Enhanced Model 705 3x0201Analog InputTransducer
Orion Jupiter Model 2xx0101Analog InputTransducer
Description:Calibration Low Point
Unit:SENSOR_UNIT
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:Cal Point Lo is the lower calibrated point of Sensor Value in sensor units. It refers to Probe Level Lo.

+2 reference(s) hidden.
Smar International Co.IF3020407Transducer
LD2920407Transducer
Description:Calibration Low Point
Unit:CAL_UNIT
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:The lowest calibrated point.

+2 reference(s) hidden.
Yamatake CorporationDSTJ 3000 NewAce0103DSTTransducer
0104DSTTransducer
Description:Calibration Low Point
Unit:CAL_UNIT
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:Low value for Cal routine

+1 reference(s) hidden.
ABB Automation Products GmbHTB82PH0101TB82PH pH, ORP, pIONTransducer
Description:Calibration Low Point
Unit:CAL_UNIT
Category:Standard
Access:Engineer
Type:32 bit Float
Help:CAL_POINT_LO: Calibration lowest point.TWO-POINT calibration procedure: 1. For PRIMARY VALUE TYPE=pH write the two-point calibration temperature into CAL_TEMP. Send the value to the instrument. (For ORP and pION this step is not necessary.)2. Apply low point calibration input. Observe PRIMARY VALUE and make sure it is stable. Write the desired calibration value into CAL_POINT_LO.3. Apply high point calibration input. Observe PRIMARY VALUE and make sure it is stable. Write the desired calibration value into CAL_POINT_HI.4. Any calibration errors will be available in EXTENDED STATUS.

+1 reference(s) hidden.
Siemens AGSITRANS LR2500101LevelTransducer
Description:Calibration Low Point
Unit:SENSOR_RANGE.UNITS_INDEX
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:No Help Available

+1 reference(s) hidden.
VEGA Grieshaber KGVEGACAL0101Analog InputTransducer
Description:Calibration Low Point
Category:Standard
Access:Engineer
Type:32 bit Float
Help:Min/Max-Adjustment: This is the lower calibrated point of the sensor. It refers to 'cal_level_lo'. The unit is defined in 'sensor_range.Units Index'