Emerson Process ManagementRosemount 5300 Series0107Advanced ConfigurationTransducer
Description:Close distance
Unit:RADAR_LEVEL_RANGE.UNITS_INDEX
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:This parameter defines a window centered at the current surface position where new surface echo candidates can be selected. The size of the window is +/- Close Distance. Echoes outside this window will not be considered as surface echoes.

+1 reference(s) hidden.
Emerson Process ManagementRosemount 5600 TankRadar PRO0201Transducer
Description:Close distance
Unit:RADAR_LEVEL_RANGE.UNITS_INDEX
Category:Vendor
Access:Engineer
Type:32 bit Float
Help:This parameter defines a window centered at the current surface position in which new surface echo candidates can be selected. The size of the window is ± CloseDist. Echoes outside this window will not be considered as possible surface echoes. The gauge will without delay jump to the strongest echo inside this window.