| Parameters | Units | About | Contact | |||||||||
| + | 8 like(s) hidden. |
| + | 23 reference(s) hidden. |
| EIM Controls Inc. | DCM Fieldbus Actuator | 0201 | Resource | |
| Emerson Process Management | El-O-Matic 22C0 | 0501 | Resource | |
| El-O-Matic DD30 | 0401 | Resource | ||
| Fisher DVC6200f / DVC6000f | 0203 | Resource | ||
| Rosemount 2051 | 0101 | Resource | ||
| Rosemount 3095 MultiVariable Transmitter | 0103 | Resource | ||
| Rosemount 5300 Series | 0107 | Resource | ||
| Rosemount 5400 Series | 0201 | Resource | ||
| 0203 | Resource | |||
| Rosemount 5600 TankRadar PRO | 0103 | Resource | ||
| 0201 | Resource | |||
| Rosemount 644 | 0107 | Resource | ||
| Rosemount 848T | 0601 | Resource | ||
| Rosemount 8742C | 0501 | Resource | ||
| Rosemount 8800 | 0701 | Resource | ||
| 0901 | Resource | |||
| Rosemount Analytical 5081-A-FF | 0101 | Resource | ||
| Rosemount Analytical 5081-C/T-FF | 0101 | Resource | ||
| Rosemount Analytical 5081-pH/ORP-FF | 0101 | Resource | ||
| Rosemount Analytical Oxymitter 5000 | 0303 | Resource | ||
| 0401 | Resource | |||
| MTL Instruments | 9331-T1 | 0101 | Resource | |
| Numatics Inc. | FF Valve Manifold | 0101 | Resource |
| Description: | Detailed Status |
| Size: | 4 |
| Category: | Vendor |
| Access: | View Only |
| Type: | bit Array |
| Help: | Additional status bit string |
| Enumerations: | 0 – LOI Error 1 – Sensor Transducer Error 2 – Manufacturing Block Integrity Error 3 – HW/SW Incompatible 4 – NV Integrity Error 5 – Register Test Failure 6 – ROM (Flash) Integrity Error 7 – RAM Integrity Error |
| + | 5 reference(s) hidden. |
| Emerson Process Management | Rosemount 3051 | 1707 | Resource | |
| Rosemount Analytical 1500XA | 0101 | Resource | ||
| Rosemount Analytical 5081-A-FF | 0206 | Resource | ||
| Rosemount Analytical 5081-C/T-FF | 0206 | Resource | ||
| Rosemount Analytical 5081-pH/ORP-FF | 0204 | Resource |
| Description: | Detailed Status |
| Size: | 4 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | bit Array |
| Help: | Detailed Status |
| Enumerations: | 0 – LOI Error 1 – Sensor Transducer Error 2 – Manufacturing Block Integrity Error 3 – HW/SW Incompatible 4 – NV Integrity Error 5 – Register Test Failure 6 – ROM (Flash) Integrity Error 7 – RAM Integrity Error 8 – ADB Transducer Block Error 9 – NV Writes Deferred 10 – Lost Deferred NV Data 11 – Mass Flow TB Error |
| + | 3 reference(s) hidden. |
| Emerson Process Management | Rosemount 3144P | 0105 | Resource | |
| Rosemount 8742C | 0501 | Transducer | ||
| Numatics Inc. | FF Valve Manifold | 0101 | Logic | Transducer |
| Description: | Detailed Status |
| Size: | 4 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | bit Array |
| Enumerations: | 0 – LOI Error 1 – Sensor Transducer Error 2 – Manufacturing Block Integrity Error 3 – HW/SW Incompatible 4 – NV Integrity Error 5 – Register Test Failure 6 – ROM (Flash) Integrity Error 7 – RAM Integrity Error 8 – ADB Transducer Error 9 – NV Writes Deferred 10 – Lost Deferred NV Data |
| + | 1 reference(s) hidden. |
| Emerson Process Management | Rosemount Analytical 1500XA | 0101 | GC | Transducer |
| Description: | Detailed Status |
| Child(s): | 1 – SOLENOID_STATUS 2 – TEMP_CTRL_STATUS 3 – PRES_CTRL_STATUS 4 – MISC_STATUS |
| Size: | 12 |
| Category: | Vendor |
| Access: | View Only |
| Type: | Structure |
| Help: | Detailed Status values show detailed informationabout errors detected by or reported to the transducer block |
| + | 1 reference(s) hidden. |
| Numatics Inc. | FF Valve Manifold | 0101 | Input/Output | Transducer |
| Description: | Detailed Status |
| Size: | 4 |
| Category: | Vendor |
| Access: | View Only |
| Type: | bit Array |
| Help: | Detailed status of the IO transducer block. |
| Enumerations: | 20 – IO BOARD DELAYED PERIODIC MSG 21 – IO BOARD PERIODIC CHKSUM ERR 22 – IO BOARD COP ERR 23 – IO BOARD EEPROM ERR 24 – OUT PULSE COUNT OVER LIMIT 25 – IN PULSE COUNT OVER LIMIT 26 – IB PROTOCOL REV MISMATCH 27 – NUM PNEUM OUTS NOT INITIALIZED 28 – MODULE TYPE MISMATCH 29 – IB COMM ERROR 30 – OUTPUT FAILURE 31 – INPUT FAILURE |