Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
+1 reference(s) hidden.
ABB Automation Products GmbHFSM40000201DiagnosisTransducer
Description:Diagnosis History Register
Size:4
Category:Vendor
Access:View Only
Type:bit Array
Help:The Diagnosis History Register shows errors and warnings, which were set in the past tense or still set.
Enumerations:0 – Max Coil Temperature
1 – Min Coil Temperature
2 – Max Coil Resistance
3 – Min Coil Resistance
4 – Max Coil Voltage
5 – Min Coil Voltage
6 – Max Coil Current
7 – Min Coil Current
8 – Max Electrode Voltage E2
9 – Min Electrode Voltage E2
10 – Max Electrode Voltage E1
11 – Min Electrode Voltage E1
12 – Max Linearity
13 – Min Linearity
14 – Max Coil Isolation Resistance
15 – Min Coil Isolation Resistance
18 – Max Signal/Noise Ratio
19 – Min Signal/Noise Ratio
20 – Max DAC Value
21 – Min DAC Value
22 – Max Electrode Balance
23 – Min Electrode Balance
28 – Electrodes not connected
31 – Ground Short Circuit Coil