Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
+1 reference(s) hidden.
Emerson Process ManagementRosemount 5600 TankRadar PRO0103Transducer
Description:Diagnostic Device Error
Size:4
Category:Vendor
Access:View Only
Type:bit Array
Help:Shows the health and status of the transmitter
Enumerations:6 – SW Version Warning
7 – SW Warning
8 – Configuration Warning
9 – Other HW Warning
10 – Analog Out Warning
11 – Display Warning
12 – Microwave Unit Warning
13 – DB Warning
14 – SW error
15 – Configuration Error
16 – Other HW Error
17 – Analog Out Error
18 – Display Error
19 – Microwave Unit Error
20 – DB Error
21 – Conf. Reg. Pwd. Enabled
22 – Full Tank
23 – Empty Tank
24 – Tank Signal Clip Warning
25 – No Surface echo
26 – Invalid ATP
27 – Volume Measurement Failure
28 – Temperature Measurement Failure
29 – Level Measurement Failure
30 – FF Card to Gauge Comm Fault

+1 reference(s) hidden.
Emerson Process ManagementRosemount 5600 TankRadar PRO0201Transducer
Description:Diagnostic Device Error
Size:4
Category:Vendor
Access:View Only
Type:bit Array
Help:Shows the health and status of the transmitter. If any hardware or software errors are present in the device they are listed here.
Enumerations:6 – SW Version Warning
7 – SW Warning
8 – Configuration Warning
9 – Other HW Warning
10 – Analog Out Warning
11 – Display Warning
12 – Microwave Unit Warning
13 – DB Warning
14 – SW error
15 – Configuration Error
16 – Other HW Error
17 – Analog Out Error
18 – Display Error
19 – Microwave Unit Error
20 – DB Error
21 – Conf. Reg. Pwd. Enabled
22 – Full Tank
23 – Empty Tank
24 – Tank Signal Clip Warning
25 – No Surface echo
26 – Invalid ATP
27 – Volume Measurement Failure
28 – Temperature Measurement Failure
29 – Level Measurement Failure
30 – FF Card to Gauge Comm Fault