Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
+4 reference(s) hidden.
Honeywell Field SolutionsTWC90000201Resource
TWM90000201Resource
Krohne Messtechnik GmbHOPTIMASS MFC3000101Resource
OPTISONIC UFC300-IL0101Resource
Description:diagnosis device
Category:Vendor
Access:View Only
Type:Enumeration
Enumerations:0 – Startup phase
1 – F Device Error
2 – F Configuration
3 – F Parameter
4 – F Software User Interface
5 – F Hardware Detection
6 – F Hardware Settings
7 – F Display
8 – F RAM/ROM Error IO1
9 – F IO 1
10 – F RAM/ROM Error IO2
11 – F IO 2
12 – F Fieldbus
13 – F Current Output C
14 – F Current Output B
15 – F Current Output A
16 – F Sensor Electronics
17 – F SE Drive Failure
18 – F SE Data Error
19 – F Sensor: Local Data Error
20 – F Sensor: Global Data Error
21 – F SE Hardware Failure
22 – F SE Data Different
23 – F SE Defective
24 – F Interface PCB Failure
25 – F SE Wiring Error
26 – F 2 2 Phase Flow
27 – F RS485/Modbus
28 – reserved 028
29 – reserved 029
30 – reserved 030
31 – reserved 031
32 – reserved 032
33 – F Application Error
34 – F Backup 2 Settings
35 – F Backup 1 Settings
36 – F Factory Settings
37 – F Active Settings
38 – F Over Range C
39 – F Wiring B
40 – F Wiring A
41 – F Over Range B (current)
42 – F Over Range A (current)
43 – F Over Range A (pulse)
44 – F Over Range B (pulse)
45 – F Over Range D
46 – F Open Circuit C
47 – F Open Circuit B
48 – F Open Circuit A
49 – F Sensor Exceeding Limit
50 – F Sensor Exceeding Limit
51 – F Sensor Electronics
52 – F Tube Not Oscillating
53 – F System Control
54 – F Stop Mode
55 – reserved 055
56 – reserved 056
57 – reserved 057
58 – F Sensor: System Error
59 – F SE Comms. Failure
60 – reserved 060
61 – reserved 061
62 – reserved 062
63 – reserved 063
64 – reserved 064
65 – S Out Of Specification
66 – S Backplane Invalid
67 – S Overflow Totaliser 1
68 – S Overflow Totaliser 3
69 – S Overflow Totaliser 1
70 – S Overflow Totaliser 2
71 – S Density Calib. Failed
72 – S Sensor Signal Error
73 – S Excessive Noise
74 – S External Vibration
75 – S Sensor Levels
76 – S Temperature Drift
77 – S Tube Asymmetry
78 – S System Control
79 – S SE PCB Temperature
80 – S Tube Temperature
81 – S Density
82 – S Startup
83 – S Power Fail
84 – S BE PCB Temperature
85 – S Res. Circ. Defective
86 – S SE Defective
87 – S 2 Phase Flow
88 – S Interface PCB Fault
89 – C Checks In Progress
90 – C Sensor Electronics
91 – C Standby Mode
92 – C Zero Calibration
93 – reserved 093
94 – reserved 094
95 – reserved 095
96 – reserved 096
97 – I Optical Interface
98 – I Backplane Difference
99 – I Backplane Settings
100 – I Backplane Sensor
101 – I Over Range Display 1
102 – I Over Range Display 2
103 – I Control Input A act.
104 – I Control Input B act.
105 – I Power Fail
106 – I Totaliser 1 Stopped
107 – I Totaliser 3 Stopped
108 – I Totaliser 1 Stopped
109 – I Totaliser 2 Stopped
110 – I Baudrate Search
111 – I No Data Exchange
112 – I Write Cycles Overfl.
113 – reserved 113
114 – reserved 114
115 – reserved 115
116 – reserved 116
117 – reserved 117
118 – reserved 118
119 – reserved 119
120 – reserved 120
121 – reserved 121
122 – reserved 122
123 – reserved 123
124 – reserved 124
125 – reserved 125
126 – reserved 126
127 – reserved 127
128 – reserved 128
255 – no message