| Parameters | Units | About | Contact | |||||||||
| + | 2 reference(s) hidden. |
| Emerson Process Management | Rosemount 5400 Series | 0203 | Transducer | |
| Rosemount 5600 TankRadar PRO | 0103 | Transducer |
| Description: | Product Dielectric Constant |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Select the Product Dielectric Constant range that applies to the product in the tank. If Unknown is selected a default value will be used. |
| Enumerations: | 0 – Unknown 1 – Range (1-2.5) 2 – Range (2.5-4) 3 – Range (4-10) 4 – Range (>10) |
| + | 1 reference(s) hidden. |
| Emerson Process Management | Rosemount 5600 TankRadar PRO | 0201 | Transducer |
| Description: | Product Dielectric Constant |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Select the Product Dielectric Constant range that applies to the product in the tank. If Unknown is selected a default value will be used. The dielectric constant of a product defines how good microwaves are reflected by the surface. A low value indicates that the product is almost transparent to microwaves (low reflection). |
| Enumerations: | 0 – Unknown 1 – Range (1-2) 2 – Range (2-4) 3 – Range (4-10) 4 – Range (>10) |