| Metso Automation | ND9000F | 0301 | Transducer | |
| 0401 | Transducer |
| Category: | Vendor |
| Access: | View Only |
| Type: | Enumeration |
| Help: | No Help Available |
| Enumerations: | 0 – none 191 – event log initialized 241 – external reset 341 – factory defaults activated 441 – params backup restore 531 – pos calib ok 631 – calib ok 731 – mA inp calib ok 871 – test cancelled 971 – test ok 1071 – test failed 1193 – watchdog reset 1293 – board to board comm fail 1323 – pressure sensor 1 fail 1423 – pressure sensor 2 fail 1523 – pressure sensor 3 fail 1623 – spool valve sensor fail 1723 – temperature sensor fail 1853 – statistics pool fail 1993 – event pool fail 2033 – pos calib fail 2133 – ctrl tune fail 2233 – mA inp calib fail 2343 – factory settings create fail 2443 – factory settings restore fail 2552 – total operation time warning 2652 – valve full strokes warning 2752 – valve reversals warning 2852 – actuator full strokes warning 2952 – actuator reversals warning 3052 – spool valve full strokes warning 3152 – spool valve reversals warning 3252 – steady state deviation warning 3352 – dynamic state deviation warning 3452 – stiction low warning 3552 – stiction high warning 3652 – load for opening low warning 3752 – load for opening high warning 3812 – supply pressure warning 3912 – temperature warning 4012 – hunting detection warning 4114 – deviation alarm 4254 – stiction low alarm 4354 – stiction high alarm 4454 – load for opening low alarm 4554 – load for opening high alarm 4614 – spool valve problem 4714 – pneumatics problem 4814 – friction problem 4995 – continued watchdog reset 5095 – failsafe activated 5125 – position sensor fail 5225 – setpoint sensor fail 5325 – prestage shortcut 5425 – prestage cut 5595 – processor failure 5645 – parameters pool fail 5763 – control params failed 5811 – online fail recovery 5921 – io diagn fail recovery 6093 – ad restart 6150 – statistics saved 6231 – calib cancelled 6333 – pos sensor range error 6433 – calib timeout 6533 – calib start fail 6633 – calib fail 6751 – online alarm recovery 6893 – DAC comm fail 6991 – factory settings created 7091 – flash sect erased 7191 – flash sect erase fail 7254 – fieldbus comm fail rate warning 7333 – spool sensor range error 7490 – database compressed 7562 – emergency control activated 7661 – emergency control deactivated 7723 – prestage coil cut 7852 – relative open stroke warning 7952 – absolute open stroke warning 8052 – relative close stroke warning 8152 – absolute close stroke warning 8252 – open load high warning 8352 – close load high warning 8452 – open load low warning 8552 – close load low warning 8652 – valve open latency warning 8752 – pressure open latency warning 8852 – valve close latency warning 8952 – pressure close latency warning 9052 – pressure open slope warning 9152 – pressure close slope warning 9214 – valve open stuck alarm 9314 – valve close stuck alarm 9414 – valve intermediate stuck alarm 9514 – unnecessary valve movement alarm 9614 – too slow valve opening alarm 9714 – too slow valve closing alarm 9814 – excessive movement in open pos alarm 9914 – deficient movement in open pos alarm 10014 – excessive movement in close pos alarm 10114 – deficient movement in close pos alarm 10231 – pressure calib ok 10331 – ctrl tune ok 10433 – pos pressure range error 10571 – step test failed 10671 – loop test failed 10771 – db test failed 10871 – analysis test failed 10971 – spool step test failed 11071 – spool loop test failed 11171 – spool db test failed 11271 – wc test failed 11371 – step test ok 11471 – loop test ok 11571 – analysis test ok 11671 – spool step test ok 11771 – spool loop test ok 11871 – spool db test ok 11971 – wc test ok 12071 – db test ok 12131 – one point cal ok 12231 – one point cal failed 12331 – calib supply pressure failure 12471 – test supply pressure failure 12511 – online supply pressure recovery 12611 – online temperature recovery 12711 – online deviation recovery 12811 – online hunting detection recovery 12911 – online spool valve problem recovery 13011 – online pneumatics problem recovery 13111 – online friction problem recovery 13212 – too low supply for 1act warning 13311 – online too low supply for 1act recovery 13452 – valve reversals trend warning 13552 – setpoint reversals trend warning 13652 – valve travel trend warning 13752 – valve reversals while ssp trend warning 13852 – load for closing low warning 13952 – load for closing high warning 14054 – load for closing low alarm 14154 – load for closing high alarm 14223 – prestage shortcut 14321 – prestage shortcut recovery 14421 – prestage cut recovery 65535 – any |
| + | 1 reference(s) hidden. |
| Metso Automation | VG9000F | 0107 | Transducer |
| Category: | Vendor |
| Access: | View Only |
| Type: | Enumeration |
| Help: | Event log events. |
| Enumerations: | 0 – None 191 – Event Log Initialized 241 – External Reset 341 – Factory Defaults Activated 441 – Parameters Backup Restored 531 – Position Calibration Successful 631 – Calibration Successful 731 – mA Input Calibration Successful 871 – Test Cancelled 971 – Test Ok 1071 – Test Failed 1193 – Continued Watchdog Reset 1293 – Fieldbus Communication Failure Rate Limit Exceeded 1323 – Pressure Sensor 1 Failure Detected 1423 – Pressure Sensor 2 Failure Detected 1523 – Pressure Sensor 3 Failure Detected 1623 – Spool Valve Sensor Failure Detected 1723 – Temperature Sensor Failure Detected 1853 – Statistics Database Error Detected 1993 – Event Database Error Detected 2033 – Position Calibration Failed 2133 – Control Tuning Failed 2233 – mA Input Calibration Failed 2343 – Factory Settings Create Failure Detected 2443 – Factory Settings Restore Failure Detected 2552 – Total Operation Time Counter Limit Exceeded 2652 – Valve Full Strokes Counter Limit Exceeded 2752 – Valve Reversals Counter Limit Exceeded 2852 – Actuator Full Strokes Counter Limit Exceeded 2952 – Actuator Reversals Counter Limit Exceeded 3052 – Spool Valve Full Strokes Counter Limit Exceeded 3152 – Spool Valve Reversals Counter Limit Exceeded 3252 – Steady State Deviation Trend Limit Exceeded 3352 – Dynamic State Deviation Trend Limit Exceeded 3452 – Stiction Trend Low Limit Exceeded 3552 – Stiction Trend High Limit Exceeded 3652 – Load For Opening Trend Low Limit Exceeded 3752 – Load For Opening Trend High Limit Exceeded 3812 – Supply Pressure Limit Exceeded 3912 – Temperature Limit Exceeded 4012 – Hunting Detected 4114 – Deviation Detected 4254 – Stiction Low Limit Exceeded 4354 – Stiction High Limit Exceeded 4454 – Load For Opening Low Limit Exceeded 4554 – Load For Opening High Limit Exceeded 4614 – Spool Valve Stuck Detected 4714 – Pneumatics Problem Detected 4814 – Friction Problem Detected 4995 – Continued Watchdog Reset 5095 – Failsafe Active 5125 – Position Sensor Failure Detected 5225 – Setpoint Sensor Failure Detected 5325 – Prestage Shortcut Detected 5425 – Prestage Cut Detected 5595 – Processor Failure Detected 5645 – Parameters Pool Failure Detected 5763 – Control Parameters Failure Detected 5811 – Failure Recovery 5921 – Sensor Failure Recovery 6093 – " " 6150 – Statistics Saved 6231 – Calibration Cancelled 6333 – Position Sensor Range Error Detected 6433 – Calibration Timeout 6533 – Calibration Start Failed 6633 – Calibration Failed 6751 – Limit Recovery 6893 – Position Transmitter Not Activated 6991 – Factory Settings Created 7091 – Flash Sector Erased 7191 – Flash Sector Erase Failure Detected 7254 – Fieldbus Comminucation Failure Rate Limit Exceeded 7333 – Spool Sensor Range Error Detected 7490 – Database Compressed 7562 – Emergency Control Activated 7661 – Emergency Control Deactivated 7723 – Prestage Cut Detected 7852 – Open Stroke Deviation Trend Limit Exceeded 7952 – Too High Total Stroke Time Open Detected 8052 – Close Stroke Deviation Trend Limit Exceeded 8152 – Too High Total Stroke Time Close Detected 8252 – Open Load High Limit Exceeded 8352 – Close Load High Limit Exceeded 8452 – Open Load Low Limit Exceeded 8552 – Close Load Low Limit Exceeded 8652 – Valve Reaction Time Open Exceeded 8752 – Spool Valve Reaction Time Open Exceeded 8852 – Valve Reaction Time Close Exceeded 8952 – Spool Valve Reaction Time Close Exceeded 9052 – Pressure Open Slope Limit Exceeded 9152 – Pressure Close Slope Limit Exceeded 9214 – Valve Open Stuck Detected 9314 – Valve Close Stuck Detected 9414 – Valve Intermediate Stuck Detected 9514 – Unintended Valve Movement Detected 9614 – Too Slow Valve Opening Detected 9714 – Too Slow Valve Closing Detected 9814 – Excessive Movement In Open Position Detected 9914 – Deficient Movement In Open Position Detected 10014 – Excessive Movement In Close Position Detected 10114 – Deficient Movement In Close Position Detected 10231 – Pressure Calibration Successful 10331 – Control Tuning Successful 10433 – Position Pressure Range Error Detected 10571 – Multipoint Step Test Failed 10671 – Dynamic Loop Test Failed 10771 – Valve Deadband Test Failed 10871 – Valve Analysis Test Failed 10971 – Spool Step Test Failed 11071 – Spool Loop Test Failed 11171 – Spool Deadband Test Failed 11271 – " " 11371 – Multipoint Step Test Succcessful 11471 – Dynamic Loop Test Successful 11571 – Valve Analysis Test Successful 11671 – Spool Step Test Successful 11771 – Spool Loop Test Successful 11871 – Spool Deadband Test Successful 11971 – " " 12071 – Valve Deadband Test Successful 12131 – One Point Calibration Successful 12231 – One Point Calibration Failed 12331 – Calibration Supply Pressure Failure Detected 12471 – Test Supply Pressure Failure Detected 12511 – Supply Pressure Back In Limits 12611 – Temperature Back In Limits 12711 – Deviation Problem Recovery 12811 – Hunting Problem Recovery 12911 – Spool Valve Problem Recovery 13011 – Pneumatics Problem Recovery 13111 – Friction Problem Recovery 13212 – Supply Pressure For Single Acting Actuator Low Limit Exceeded 13311 – Supply Pressure For Single Acting Actuator Back In Limits 13452 – Valve Reversals Trend Limit Exceeded 13552 – Setpoint Reversals Trend Limit Exceeded 13652 – Valve Travel Trend Limit Exceeded 13752 – Valve Reversals While Stable Setpoint Trend Limit Exceeded 13852 – Load For Closing Trend Low Limit Exceeded 13952 – Load For Closing Trend High Limit Exceeded 14054 – Load For Closing Low Limit Exceeded 14154 – Load For Closing High Limit Exceeded 14223 – Prestage Shortcut Detected 14321 – Prestage Shortcut Recovery 14421 – Prestage Cut Recovery 14511 – Valve Open Stuck Recovery 14611 – Valve Close Stuck Recovery 14711 – Valve Intermediate Stuck Recovery 14811 – Unallowed Valve Movement Recovery 14911 – Too Slow Valve Opening Recovery 15011 – Too Slow Valve Closing Recovery 15114 – Too Fast Valve Opening Detected 15214 – Too Fast Valve Closing Detected 15311 – Too Fast Valve Opening Recovery 15411 – Too Fast Valve Closing Recovery 15552 – Supply Pressure Trend Limit Exceeded 15652 – Temperature Trend Limit Exceeded 15723 – Position Sensor Failure Detected 15815 – Supply Pressure Limit Exceeded 15916 – Supply Pressure Back In Limits 16091 – Failsafe Recovery 16114 – Control Adaption Problem Detected 16211 – Control Adaption Problem Recovery 16312 – Reduced Performance Activated 16411 – Reduced Performance Deactivated 16512 – Supply Pressure Drop Detected 16611 – Supply Pressure Drop Recovery 16723 – Position Sensor Out Of Range 16820 – Prestage Shortcut Candidate Detected 16971 – Automatic Partial Stroke Test Start Failed 17071 – Self Test Start Failed 17171 – Manual Emergency Trip Test Start Failed 17271 – Automatic Partial Stroke Test Failed 17371 – Self Test Failed 17471 – Manual Emergency Trip Test Failed 17571 – Test Parameterization Failed 17674 – Test Timeout Detected 17714 – Test Overshoot Detected 17814 – Pressure Drop Detected During test 17914 – Valve Position Changed During Pneumatics Test 18071 – Automatic Partial Stroke Test Successful 18171 – Self Test Successful 18271 – Manual Emergency Trip Test Successful 18371 – Automatic Partial Stroke Test Cancelled 18471 – Self Test Cancelled 18571 – Manual Emergency Trip Test Cancelled 18671 – Manual Partial Stroke Test Start Failed 18771 – Manual Partial Stroke Test Failed 18871 – Manual Partial Stroke Test Successful 18971 – Manual Partial Stroke Test Cancelled 19052 – Partial Stroke Test Counter Limit Exceeded 19174 – Emergency Trip Active 19252 – Partial Stroke Test Loadfactor Trend Low Limit Exceeded 19352 – Partial Stroke Test Loadfactor Trend High Limit Exceeded 19452 – Partial Stroke Test Breakaway Pressure Trend Low Limit Exceeded 19552 – Partial Stroke Test Breakaway Pressure Trend High Limit Exceeded 19652 – Emergency Trip Test Loadfactor Trend Low Limit Exceeded 19752 – Emergency Trip Test Loadfactor Trend High Limit Exceeded 19852 – Emergency Trip Test Breakaway Pressure Trend Low Limit Exceeded 19952 – Emergency Trip Test Breakaway Pressure Trend High Limit Exceeded 20052 – Emergency Trip Test Valve Full Stroke Time Open High Limit 20052 20152 – Emergency Trip Test Valve Full Stroke Time Close High Limit20152 20274 – Alarm State Prevents Test 20391 – Device Usage Changed, Reboot required 20471 – Device Test Restricted 20571 – Alarm state reseted 20631 – Pressure calibration failed 20731 – Transmitter calibration successful 20831 – Transmitter calibration failed 20931 – Coil calibration successful 21031 – Coil calibration failed 21171 – Test disabled 21271 – Invalid Test Start Position 21371 – Test Not Allowed in this Device Usage 21471 – Test Control Channel Reservation Failed 21571 – Pneumatics Test failed: no change in cylinder pressures 21631 – Supply pressure level too low to execute calibration 21731 – Calibration tried to start while emergency line is active 21831 – Calibration tried to start while other calibration is running 21931 – Calibration tried to start while device is in ALARM state 22014 – Housing Pressure Limit Exceeded 22111 – Housing Pressure back in limits |