| SAMSON AG | 373x-5 | 0201 | Advanced PV | Transducer |
| Description: | Message 2 |
| Parent: | EVENT_LOGGING_1 |
| Category: | Vendor |
| Access: | View Only |
| Type: | Enumeration |
| Help: | Apprehended message, set by the positioner. |
| Enumerations: | 0 – No message logged 1 – Init. error: x > range 2 – Init. error: Delta x < range 3 – Init. error: Mech./Pneu. (Attachment) 4 – Init. error: Init. time exceeded 5 – Init. error: Init./int. solenoid valve 6 – Init. error: Travel time too short 7 – Init. error: Pin position/safety switch 8 – Init. error: No emergency mode 9 – Init. error: Safety switch defective 10 – Oper. error: Control loop 11 – Oper. error: Zero point 12 – Oper. error: Autocorrection 13 – Oper. error: Fatal error 15 – Oper. error: Total valve travel exceeded 17 – HW error: x-signal 18 – HW error: i/p converter 19 – HW error: Hardware 20 – HW error: Data memory 21 – HW error: Control calculation 22 – HW error: Program load error 23 – HW error: Initialization switch defective 24 – Data error: Control parameter 25 – Data error: Poti parameter 26 – Data error: Adjustment parameter 27 – Data error: General parameter 28 – Data error: Internal device error 1 29 – Data error: HART Parameter 30 – Data error: Info parameter 31 – Data error: Options parameter 32 – Data error: Diagnosis parameter 33 – Kp: manipulation 34 – Tv: manipulation 51 – Initialization was aborted 2000 – Oper. error: Mode unequal AUTO 2001 – Set to fail-safe via SET_FAIL_SAFE_POS (Set to fail-safe pos2001 10000 – Range: Mostly near closing pos. 10001 – Range: Mostly near max. opening 10002 – Range: Mostly closing pos. 10003 – Range: Mostly max. opening 10005 – Trend range: Shift. work. range closing pos. 10006 – Trend range: Shift. work. range max. opening pos. 10008 – Limit range: Down 10009 – Limit range: Up 10010 – Limit range: Modification impossible 10012 – Trend end pos.: ZP-shift mon.e down; aver. > ref. 10013 – Trend end pos.: ZP-shift mon. up; aver. > ref. 10014 – Trend end pos.: ZP-shift alt.; aver. > ref. 10015 – Trend end pos.: ZP-shift mon. down; aver. < ref. 10016 – Trend end pos.: ZP-shift mon. up; aver. < ref. 10017 – Trend end pos.: ZP-alternate; aver. < ref. 10019 – Mech. conn. Pos./Valve: No opt. travel transm.TEST 10020 – Mech. conn. Pos./Valve: Perhaps loose 10021 – Mech. conn. Pos./Valve: Perhaps limit. range 10023 – Spring: Perhaps spring stiffness reduced TEST 10024 – Spring: Perhaps bias reduced TEST 10025 – Spring: Perhaps bias increased TEST 10026 – Spring: Working at full capacity 10027 – Spring: Working at full capacity TEST 10029 – Air supply: Perhaps modified TEST 10030 – Air supply: Perhaps not enough TEST 10031 – Air supply: Perhaps not enough 10032 – Air supply: Working at full capacity 10033 – Air supply: Working at full capacity TEST 10034 – Air supply: Perhaps modified 10035 – Leakage Pneumatics: Perhaps existing TEST 10036 – Leakage Pneumatics: Perhaps too large TEST 10037 – Leakage Pneumatics: Perhaps too large 10038 – Leakage Pneumatics: Perhaps existing 10039 – Friction: Much higher over whole range 10040 – Friction: Much lower over whole range 10041 – Friction: Much higher over section 10042 – Friction: Much lower over section 10044 – Inner leakage: Alarm limit 2 exceeded 10045 – Inner leakage: Alarm limit 3 exceeded 10046 – Inner leakage: Perhaps existing 10047 – Ext. leakage: Perhaps soon expected 10048 – Ext. leakage: Perhaps existing 10049 – Ext. leakage: Existing 10060 – Temperature below -40°C/-40°F 10062 – Temperature above +80°C/+176°F 10070 – Data logger started by travel 10071 – Data logger started by int. solenoid valve/forced vent. 10072 – Data logger started by setpoint 10073 – Data logger started by int. sol. valve/forced venting 10074 – Data logger started by actual value 10075 – Data logger started by setpoint deviation 10076 – Data logger started by drive signal 10077 – Data logger started by binary input 10078 – Data logger started by condensed state 10079 – Data logger started by binary input 1 10080 – Data logger started by binary input 2 10081 – Data logger started by discrete output 1 10082 – Data logger started by discrete output 2 11020 – Mech. conn. Pos./Valve: Perhaps loose TEST 11039 – Friction: Much higher over whole range TEST 11040 – Friction: Much lower over whole range TEST 11041 – Friction: Much higher over section TEST 11042 – Friction: Much lower over section TEST 11100 – Diagnosis reset performed 11110 – No reference recording after initialization 12000 – Reset long-term histogram X 12001 – Reset long-term histogram cycle counter 12002 – Reset elapsed hours meter 12003 – Reset temp. meter and high. values 12004 – Reset long-term view Y-steady online 12005 – Reset long-term view hysteresis online 12006 – Reset end pos. trend ref. value upper end pos. 12007 – Reset end pos. trend ref. value lower end pos. 12008 – Long-term sound sensor: reset meas. whole range 12009 – Reset long-term process values histogram 12010 – Reset long-term histogram deviation 12021 – Current too low: i/p converter switched-off safely 12050 – Switching state determined via binary input 12051 – Local operation write protection activated via binary input 12052 – Partial Stroke Test (PST) activated via binary input 12053 – Set to fail-safe reference variable via binary input 12054 – Switch between AUTO / MAN via binary input 12055 – Data logger launched via binary input 12056 – Reset diagnosis via binary input 12057 – External solenoid valve determined via binary input 12058 – Leakage detection determined via binary input 12450 – Leakage: abort. test d8: int. sol. valve 12451 – Leakage: abort. test d8: test time exceeded 12452 – Leakage: abort. test d8: meas. point not reachable 12453 – Leakage: abort. test d8: man. aborted 12461 – Leakage: abort. test d8: level alt. too small 12462 – Leakage: abort. test d8: level alt. too late 12470 – Leakage: abort. test d9: int. sol. valve 12471 – Leakage: abort. test d9: test time exceeded 12472 – Leakage: abort. test d9: meas. point not reachable 12473 – Leakage: abort. test d9: man. aborted 12481 – Leakage: abort. test d9: level alt. too small 12482 – Leakage: abort. test d9: level alt. too late 12490 – Leakage: reset analysis test d8 12491 – Leakage: reset analysis test d9 12492 – Leakage: reset short term diagram 12493 – Leakage: reset long term diagram 12494 – Leakage: reset level monitoring 12498 – Leakage: Cannot start test d9 - no test d8 started 12499 – Leakage: Alarm limit d9-test set to factory settings 12500 – Internal solenoid valve/forced venting activated 12510 – Overflow of the operating hours counter 12520 – PST: Status 'No test available' activated 12521 – PST: Status 'x cancellation' activated 12522 – PST: Status 'delta y cancellation' activated 12523 – PST: Status 'Tolerance band exceeded' activated 12524 – PST: Status 'Max. test time exceeded' activated 12525 – PST: Status 'Test manually cancelled' activated 12526 – PST: Status 'Measured data storage out of memory' activated 12527 – PST: Status 'Aborted by int. solenoid valve/forced venting'12527 12528 – PST: Status 'Supply pressure / friction' activated 12529 – PST successful 12530 – PST: Status 'Difference w - step start too high' activated 12531 – PST: Status 'Test aborted-ref. var. was changed' activated 12532 – PST: Status 'Current too low' activated 12533 – PST: Status 'Test aborted - Max. break away time exceeded' 12533 12534 – PST: Status 'Test aborted - Max. period to step end exceede12534 12544 – FST: Status 'Max. test time exceeded' activated 12545 – FST: Status 'Test manually cancelled' activated 12546 – FST: Status 'Measured data storage out of memory' activated 12547 – FST: Status 'Aborted by int. solenoid valve/forced venting'12547 12548 – FST: Status 'Supply pressure/friction' activated 12549 – FST successful 12550 – FST: Status 'Difference w - step start too high' activated 12551 – FST: Status 'Test aborted - ref. var. was changed' activated 12552 – FST: Status 'Current too low' activated 12553 – FST: Status 'Test aborted - Max. break away time exceeded' 12553 12554 – FST: Status 'Test aborted - Max. period to step end exceede12554 12600 – O/C: break loose time rising 12601 – O/C: break loose time falling 12602 – O/C: transit time rising 12603 – O/C: transit time falling 12604 – O/C: travel end value not reachable 12605 – O/C: travel end value rising 12606 – O/C: travel end value falling |