Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
USED_FFT_WINDOW_FUNC

+1 reference(s) hidden.
Emerson Process ManagementRosemount 5600 TankRadar PRO0201Transducer
Description:Fast Fourier transform window function
Category:Vendor
Access:Engineer
Type:Enumeration
Help:Defines how wide the base of an echo peak in the echo curve should be (how much energy that is focused into one peak). Choose:- Wide or Extra Wide to increase the window in which energy is focused into one peak (increased base width) when the surface may reflect multiple weak echoes (can happen for non horizontal surfaces).- Normal to get the best resolution and ability to track echoes close to each other. For liquid applications always use Normal.For solid applications this parameter is very useful. By choosing Wide or Extra Wide energy from a sloping surface can be focused into one echo peak making it easier for the device to track the surface. Accuracy of the device will be lower, but robustness will increase.
Enumerations:0 – Normal
1 – Extra Wide
2 – Wide