| Emerson Process Management | Rosemount 2051 | 0101 | Resource | |
| Rosemount 3051 | 1707 | Pressure | Transducer | |
| Rosemount 3095 MultiVariable Transmitter | 0103 | Transducer |
| Description: | Flange type |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Indicates type of flange that is attached to the device. |
| Enumerations: | 12 – Conventional 13 – Coplanar 14 – Remote seal 15 – Lvl;3in,c 150(ANSI) 16 – Lvl;4in,c 150(ANSI) 17 – Lvl;3in,c 300(ANSI) 18 – Lvl;4in,c 300(ANSI) 19 – Lvl;DN80,PN40 20 – Lvl;DN100,PN40 21 – Lvl;DN100,PN10/16 22 – Lvl;2in,c 150(ANSI) 23 – Lvl;2in,c 300(ANSI) 24 – Lvl;50DN,6PN 25 – Lvl;50DN,40PN 252 – Unknown 253 – Spcl |
| + | 2 reference(s) hidden. |
| Emerson Process Management | Rosemount 8800 | 0701 | Transducer | |
| 0901 | Transducer |
| Description: | Flange Type |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Flange Type - allows the electronics to correctly determine installation effects for the standard meter body and the high pressure meter body. |
| Enumerations: | 1 – ANSI 300 2 – ANSI 600 3 – PN 10 4 – PN 16 5 – PN 40 6 – Wafer 7 – PN 64 8 – PN 100 9 – JIS 10K 10 – JIS 16K/20K 11 – JIS 40K 12 – ANSI 900 13 – ANSI 150 14 – PN 25 15 – PN 160 16 – ANSI 1500 17 – PN 250 30 – ANSI 150 Reducer 31 – ANSI 300 Reducer 32 – ANSI 600 Reducer 33 – ANSI 900 Reducer 34 – ANSI 1500 Reducer 35 – PN 10 Reducer 36 – PN 16 Reducer 37 – PN 25 Reducer 38 – PN 40 Reducer 39 – PN 64 Reducer 40 – PN 100 Reducer 41 – PN 160 Reducer 42 – PN 250 Reducer 43 – JIS 10K Reducer 44 – JIS 16K/20K Reducer 45 – JIS 40K Reducer 253 – Special |
| + | 1 reference(s) hidden. |
| ABB Automation Products GmbH | 2600T Series 263/265 | 0101 | Pressure | Transducer |
| Description: | Flange type |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Flange type help |
| Enumerations: | 12 – Conventional 14 – Remote Seal 53 – Level Flange Type Flush 54 – Level Flange Type Extended 55 – Welded Flange 56 – Level Sanitary 57 – Level Food 58 – No Flange Direct Connection 59 – All Welded for Remote Seal 60 – Gasketed for Remote Seal 251 – None 252 – Unknown 253 – Special |
| + | 1 reference(s) hidden. |
| Emerson Process Management | Rosemount 8742C | 0501 | Resource |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Flange Type |
| Enumerations: | 1 – ANSI 300 2 – ANSI 600 3 – PN 10 4 – PN 16 5 – PN 40 6 – Wafer 7 – ANSI 900 8 – PN 25 9 – PN 64 10 – ANSI 150 252 – Other |
| + | 1 reference(s) hidden. |
| Yokogawa Electric Corporation | EJX | 0303 | Sensor | Transducer |
| Description: | Flange Type |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Defines the type of flange used in the device. |
| Enumerations: | 0 – Conventional 1 – Remote seal 2 – Level 3 – Thread 4 – Unknown 5 – Spcl |
| + | 1 reference(s) hidden. |
| Foxboro-Eckardt | 240FF | 0101 | Pressure | Transducer |
| Parent: | SENSOR_BASIC_DATA |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Flange type code |
| Enumerations: | 0 – DN 40, PN 40 1 – DN 50, PN 40 2 – DN 50, PN 100 3 – DN 50, PN 400 4 – DN 70, PN 500 5 – DN 80, PN 16 6 – DN 80, PN 40 7 – DN 80, PN 63 8 – DN 80, PN 100 9 – DN 80, PN 250 10 – DN 80, PN 400 11 – DN 100, PN 16 12 – DN 100, PN 40 13 – DN 100, PN 63 14 – DN 100, PN 100 15 – DN 100, PN 250 16 – DN 150, PN 16 17 – DN 150, PN 40 18 – 2 in, cl.150 19 – 2 in, cl.300 20 – 2 in, cl.600 21 – 2 in, cl.2500 22 – 3 in, cl.150 23 – 3 in, cl.300 24 – 3 in, cl.600 25 – 3 in, cl.900 26 – 3 in, cl.1500 27 – 3 in, cl.2500 28 – 4 in, cl.150 29 – 4 in, cl.300 30 – 4 in, cl.600 31 – 4 in, cl.900 32 – 4 in, cl.1500 33 – IG-Norm DN 70, PN 500 34 – API 10000 35 – 4 in, cl.2500 36 – DN 100, PN 400 37 – DN 15, PN 40 38 – DN 20, PN 40 39 – DN 25, PN 40 40 – 1 in, cl. 150 41 – 1 in, cl. 300 249 – Undefined 251 – None 253 – Special |