| Parameters | Units | About | Contact | |||||||||
| + | 4 reference(s) hidden. |
| Flowserve Corporation | LOGIX 3400IQ/1400 | 0501 | Proportional Integral Derivative | Function |
| Logix 3400MD | 0102 | Proportional Integral Derivative | Function | |
| Honeywell Field Solutions | STT35F | 0201 | Proportional Integral Derivative | Function |
| 0401 | Proportional Integral Derivative | Function |
| Minimum Range: | 0 |
| Maximum Range: | 250 |
| Category: | Vendor |
| Access: | Engineer |
| Type: | 32 bit Float |
| Help: | NonLinear Gain Parameter. Dimensionless gain factor. When GAIN_NLIN is multiplied by the absolute value of the error and added to the linear GAIN, the result is a gain response which is proportional to the deviation. Default is zero resulting in no response due to non-linear gain action. |