| Parameters | Units | About | Contact | |||||||||
| + | 2 reference(s) hidden. |
| Emerson Process Management | Rosemount 5400 Series | 0203 | Transducer | |
| Rosemount 5600 TankRadar PRO | 0103 | Transducer |
| Description: | Tank Bottom Type |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Select type of tank bottom. |
| Enumerations: | 0 – Unknown 1 – Flat 2 – Dome 3 – Cone 4 – Flat Inclined |
| + | 1 reference(s) hidden. |
| Emerson Process Management | Rosemount 5600 TankRadar PRO | 0201 | Transducer |
| Description: | Tank Bottom Type |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Select a Tank Bottom Type that corresponds to the actual shape of the tank bottom. The device will be optimized for the selected type. If the Tank Bottom Type for the tank is not available in the list choose Unknown.Flat - select if the bottom shape is flat with an inclination less than a few degrees (<5 degrees).Dome - select if the bottom is rounded/spherical.Cone - select if the bottom is conical with product outlet at the center of the tank.Flat inclined - select if the bottom inclination is more than a few degrees (>5 degrees) or if there are disturbing objects on the tank floor (like heating coils) right beneath the device.This parameter is only available for Vertical Cylinders and Cubical Tank Types. |
| Enumerations: | 0 – Unknown 1 – Flat 2 – Dome 3 – Cone 4 – Flat Inclined |