Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
+17 like(s) hidden.
DECIMAL DIAG EU_0 EU_100 FAULT_STATE_VALUE IO_TB_OUT_2 MODULE_TYPE OUT_2_RANGE OUT_2_UNITS PULSE_COUNT PULSE_COUNT_LIMIT SELECT_MAI_OUT_2 SLOT_DIO_NUM SLOT_NUM STATUS UNITS_INDEX VALUE

+30 reference(s) hidden.
Dresser Valve DivisionFVP0401SpliterFunction
FVP (Software Download)0202SpliterFunction
0301SpliterFunction
Emerson Process ManagementRosemount 30511707Multiple Analog InputFunction
Signal CharacterizerFunction
SpliterFunction
Rosemount 3095 MultiVariable Transmitter0103Signal CharacterizerFunction
SpliterFunction
Rosemount 3144P0105Signal CharacterizerFunction
SpliterFunction
Rosemount 5300 Series0107Signal CharacterizerFunction
SpliterFunction
Rosemount 5400 Series0203Signal CharacterizerFunction
SpliterFunction
Rosemount 848T0601Multiple Analog InputFunction
Metso AutomationND9000F0301SpliterFunction
0401SpliterFunction
MTL Instruments9331-T10101Multiple Analog InputFunction
Yokogawa Electric CorporationEJX0303Signal CharacterizerFunction
YPK0105SpliterFunction
YVP0401SpliterFunction
YVP (Software Download)0202SpliterFunction
0301SpliterFunction
Description:Output 2
Child(s):1 – STATUS
2 – VALUE
Size:5
Category:Standard
Access:Operator
Type:Structure
Help:OUT_2 help

+12 reference(s) hidden.
Metroval Controle de Fluidos Ltda.CMM-010101Constant and Contained RWFunction
Signal CharacterizerFunction
SplitterFunction
Smar International Co.FB7000407ConstantFunction
Multiple Analog InputFunction
Signal CharacterizerFunction
SplitterFunction
IF3020407ConstantFunction
Signal CharacterizerFunction
SplitterFunction
LD2920407ConstantFunction
Signal CharacterizerFunction
Description:Output 2
Child(s):1 – STATUS
2 – VALUE
Size:5
Category:Vendor
Access:Operator
Type:Structure
Help:Numbered output parameter for multiple input function blocks.

+11 reference(s) hidden.
ABB Automation Products GmbH2600T Series - Model 266 P-dP0101Signal CharacterizerFunction
EIM Controls Inc.DCM Fieldbus Actuator0201Multiple Analog InputFunction
Emerson Process ManagementFisher DVC6200f / DVC6000f0203Multiple Analog InputFunction
SpliterFunction
Rosemount Analytical 1500XA0101Multiple Analog InputFunction
Endress+HauserPROline Promag 53/550401Signal CharacterizerFunction
PROline Promass 830401Signal CharacterizerFunction
Flowserve CorporationLogix 3400MD0102SpliterFunction
Fuji Electric CorporationFCX-AIII Series0101Signal CharacterizerFunction
Metroval Controle de Fluidos Ltda.TDM-FF-010101Signal CharacterizerFunction
SAMSON AG373x-50201Multiple Analog InputFunction
Description:Output 2
Child(s):1 – STATUS
2 – VALUE
Size:5
Category:Standard
Access:Operator
Type:Structure
Help:A block output required by the OS and Analog Calculate blocks.

+4 reference(s) hidden.
Endress+HauserLevelflex M0303Signal CharacterizerFunction
Micropilot M0303Signal CharacterizerFunction
Prosonic M0303Signal CharacterizerFunction
Yokogawa Electric CorporationYVP0306SpliterFunction
Description:Output 2
Child(s):1 – STATUS
2 – VALUE
Size:5
Category:Vendor
Access:Operator
Type:Structure
Help:OUT_2 help

+1 reference(s) hidden.
Emerson Process ManagementRosemount 20510101Signal CharacterizerFunction
Description:Output 2
Child(s):1 – STATUS
2 – VALUE
Size:5
Category:Vendor
Access:Operator
Type:Structure
Help:Block output 2; one of the outputs required by the Splitter & Analog Calculate Blocks