| Parameters | Units | About | Contact | |||||||||
| + | 4 reference(s) hidden. |
| Endress+Hauser | Levelflex M | 0303 | Guided Raider Level | Transducer |
| Micropilot M | 0202 | Raider Level | Transducer | |
| 0303 | Raider Level | Transducer | ||
| Prosonic M | 0303 | Ultrasonic Level | Transducer |
| Description: | present error |
| Category: | Vendor |
| Access: | View Only |
| Type: | Enumeration |
| Help: | No Help Available |
| Enumerations: | 0 – " " 102 – checksum error general reset & new calibr.required A102 103 – initialising - please wait W103 106 – downloading please wait A106 110 – checksum error general reset & new calibr.required A110 111 – electronics defect A111 113 – electronics defect A113 114 – electronics defect A114 115 – fault power supply A115 116 – download error repeat download A116 121 – electronics defect A121 152 – checksum error general reset & new calibr.required A152 153 – initialising - please wait W153 155 – electronics defect A155 160 – checksum error general reset & new calibr.required A160 164 – electronics defect A164 171 – electronics defect A171 221 – HF module failure ch1 A221 241 – broken probe ch1 A241 251 – gland failure ch1 A251 261 – HF cable failure K1 A261 275 – electronics defect factory settings W275 511 – no factory cali- bration ch1 W511 512 – recording of mapping please wait W512 601 – linearisation ch1 curve not monotone W601 611 – less than 2 linea- risation points for channel 1 W611 621 – simulation ch. 1 on W621 641 – no usable echo channel 1 check calibr. E641 650 – Signal/noise ratio too low or no echo W650 651 – level in safety distance - risk of overspill E651 671 – linearisation ch1 not complete, not usable A671 681 – current ch1 out of range W681 |