Foundation Fieldbus Parameter Search (βeta)

"Taking the frustration out of foundation"

Parameters Units About Contact
 
Parameter:
+2 reference(s) hidden.
Emerson Process ManagementRosemount 30511707Mass FlowTransducer
Rosemount 3095 MultiVariable Transmitter0103Mass FlowTransducer
Description:Primary element type
Category:Vendor
Access:View Only
Type:Enumeration
Help:Primary element type
Enumerations:0 – Annubar (R) Diamond II (Discontinued 1999)
1 – Annubar (R) Diamond II+ / Mass ProBar
2 – Calibrated Annubar Diamond (R) II (Discontinued 1999)
3 – Calibrated Annubar Diamond (R) II+ / Mass ProBar
4 – Long Radius Wall Taps, ASME
5 – Long Radius Wall Taps, ISO
6 – ISA 1932, ISO
7 – Calibrated Cd (Nozzle)
8 – Constant Cd (Nozzle)
9 – 1195 Mass ProPlate
10 – 2 1/2D & 8D Taps, ASME
11 – Corner Taps, ASME
12 – Corner Taps, ISO
13 – D & D/2 Taps, ASME
14 – D & D/2 Taps, ISO
15 – Flange Taps, AGA
16 – Flange Taps, ASME
17 – Flange Taps, ISO
18 – Small Bore Orifice, Flange Taps, ASME
19 – Small Bore Orifice, Corner Taps, ASME
20 – Calibrated Cd: Flange, Corner D & D/2 Taps
21 – Constant Cd: Flange, Corner D & D/2 Taps
22 – Calibrated Cd: 2 1/2D & 8D Taps
23 – Constant Cd: 2 1/2D & 8D Taps
24 – Nozzle, ISO
25 – Rough Cast/Fabricated Inlet, ASME
26 – Rough Cast Inlet, ISO
27 – Machined Inlet, ASME
28 – Machined Inlet, ISO
29 – Welded Inlet, ISO
30 – Calibrated Cd (Venturi)
31 – Constant Cd (Venturi)
32 – Area Averaging Meter
33 – Standard V-Cone (R)
34 – Corner Taps, ISO 99 Amendment 1
35 – D & D/2 Taps, ISO 99 Amendment 1
36 – Flange Taps, ISO 99 Amendment 1
37 – Calibrated Cd (Mass ProPlate)
38 – Constant Cd (Mass ProPlate)
39 – 1195 Mass ProPlate, Cd with Bias
40 – Flange Taps, ISO-5167 (2002)
41 – Corner Taps, ISO-5167 (2002)
42 – D & D/2 Taps, ISO-5167 (2002)
43 – Calibrated Cd: Flange, Corner, D & D/2 Taps: ISO 5167 (2002)
44 – Constant Cd: Flange, Corner, D & D/2 Taps: ISO 5167 (2002)
45 – 405P Compact Orifice
46 – 485 Annubar (R) / 3095 MFA Mass ProBar
47 – 485 Annubar (R) / 3095 MFA Mass ProBar, Constant K
48 – Calibrated 485 Annubar (R) / 3095 MFA Mass ProBar
49 – Flange Taps, ASME MFC-3M (2003)
50 – Corner Taps, ASME MFC-3M (2003)
51 – D & D/2 Taps, ASME MFC-3M (2003)
52 – Calibrated Cd: Flange, Corner, D & D/2 Taps: ASME MFC-3M (2003)
53 – Constant Cd: Flange, Corner, D & D/2 Taps: ASME MFC-3M (2003)
54 – Wafer V-Cone (R)
55 – Calibrated Standard V-Cone (R)
56 – Calibrated Wafer-Cone (R)
57 – 405C/3095 Compact Conditioning Orifice
58 – 1595 Conditioning Orifice Plate, Corner Taps
59 – 1595 Conditioning Orifice Plate, Flange Taps
60 – 1595 Conditioning Orifice Plate, D & D/2 Taps
61 – Wedge Meter
255 – No Primary Element