| Metso Automation | ND9000F | 0301 | Transducer | |
| 0401 | Transducer |
| Category: | Vendor |
| Access: | Engineer |
| Type: | Enumeration |
| Help: | Self-calibration error code |
| Enumerations: | 0 – Indicates no error 1 – Calibration not initialized properly 2 – An invalid operation was requested 3 – Channel status was bad during calibration 4 – The test timeout has expired 5 – There is not enough pressure during position calibration 6 – The state machines have entered to unknown state 7 – Parameters write function failed when storing spool pos 8 – Parameters write function failed when storing valve pos 9 – Parameters write function failed when storing pressure c1 10 – Paraters write function failed when storing pressure c2 11 – Paraters write function failed when storing supply pressure 12 – Paraters write function failed when storing input current 13 – Spool pos values not in valid range 14 – Valve pos values not in valid range 15 – Pressure c1 values not in valid range 16 – Pressure c2 values not in valid range 17 – Supply pressure values not in valid range 18 – Input current values not in valid range 19 – Spool pos values difference too small 20 – Valve pos values difference too small 21 – Pressure c1 values difference too small 22 – Pressure c2 values difference too small 23 – Supply pressure values difference too small 24 – Input current values difference too small 25 – pressure channel C1 sensor gain invalid 26 – pressure channel C1 sensor gain diff invalid 27 – pressure channel C2 sensor gain invalid 28 – pressure channel C2 sensor gain diff invalid 29 – pressure channel SUPPLY sensor gain invalid 30 – pressure channel SUPPLY sensor gain diff invalid 31 – Calib process was not able to get the temporary ownership 32 – Unable to write Spring tuner store values into database 33 – Spring tuner store values out of valid range 34 – Unable to write pwm calibration store value into database 35 – Pwm calibration store value out of valid range 36 – Tune failed to move the valve 37 – Range error in spring tuner 38 – prestage diagnostics range 39 – range error one point cal 40 – RESERVED 40 41 – RESERVED 41 42 – RESERVED 42 43 – RESERVED 43 44 – RESERVED 44 45 – RESERVED 45 46 – RESERVED 46 47 – RESERVED 47 48 – RESERVED 48 49 – RESERVED 49 50 – RESERVED 50 |
| + | 1 reference(s) hidden. |
| Metso Automation | VG9000F | 0107 | Transducer |
| Category: | Vendor |
| Access: | View Only |
| Type: | Enumeration |
| Help: | Self-calibration error code. |
| Enumerations: | 0 – Indicates no error 1 – Calibration not initialized properly 2 – An invalid operation was requested 3 – Channel status was bad during calibration 4 – The test timeout has expired 5 – The state machines have entered to unknown state 6 – Parameters write function failed when storing valve pos 7 – Parameters write function failed when storing pressure c1 8 – Paraters write function failed when storing pressure c2 9 – Paraters write function failed when storing supply pressure 10 – Paraters write function failed when storing input current 11 – Valve pos values difference too small 12 – Pressure c1 values difference too small 13 – Pressure c2 values difference too small 14 – Supply pressure values difference too small 15 – Input current values difference too small 16 – pressure channel C1 sensor gain invalid 17 – pressure channel C1 sensor gain diff invalid 18 – pressure channel C2 sensor gain invalid 19 – pressure channel C2 sensor gain diff invalid 20 – pressure channel SUPPLY sensor gain invalid 21 – pressure channel SUPPLY sensor gain diff invalid 22 – Calib process was not able to get the temporary ownership 23 – prestage diagnostics range 24 – parameters store in valve speed 25 – Calibration not allowed - Other Calibration running 26 – Calibration not allowed - Emergency line active 27 – Supply pressure level too low for calibration 28 – Calibration not allowed - Device in ALARM state 29 – Failure to enter the calibration mode 30 – Given supply pressure level is out of range 31 – Critical parameter read failure 32 – Requested calibration type is out of range 33 – RESERVED 34 34 – RESERVED 35 35 – RESERVED 36 36 – RESERVED 37 37 – RESERVED 38 38 – RESERVED 39 39 – RESERVED 40 |